What factors influence the heating of alternators?
According to AS-PL, the primary purpose of the alternator is to meet the electrical demands of installed equipment and to recharge the battery. With an increase in said equipment, the consequence is increased consumption of the electricity supplied by the alternator. Michał Czarzasty, production director at AS-PL, dives into this subject:
Increasing the role of automation and systematically improving the comfort of motorists and passengers are some of the key motivators for the changes taking place. In some cases, a single alternator cannot cover the full electricity demand, and, in such cases, additional alternators are installed. Within 12V systems, while in the late 1950s, the power of the largest alternator was 600W, it is now around 3,000W.
One of the important factors limiting a further increase in power is the amount of heat released during the conversion of mechanical energy to electrical energy. The biggest cause of heat generation is the current flowing through the stator winding and the rectifier diodes. The alternator temperature rise depends on the generated heat dissipation rate. The temperature inside the alternator will stabilise at a value corresponding to a situation where the amount of heat released is equal to the amount of heat dissipated.
In modern alternators, the permissible temperature depends on the thermal resistance of the weakest component used and usually does not exceed 200°C. Given that the alternator is usually mounted to a hot engine housing, the cooling air is close to the temperature of the ICE. At present, it is assumed that the cooling air temperature can be 130°C, which, consequently, causes the permissible alternator temperature rise to be significantly limited.
Reliable operation of an alternator depends on its design, allowing a considerable amount of heat generated inside to be effectively dissipated outside. Initially (until the 1970s), alternators had an external fan (Fig 1), but this method of cooling at increased load currents proved inadequate.
The following years saw a complete change in the cooling method: instead of an external fan, two fans were used by placing appropriate blades on both sides of the rotor (Fig 2). This change, along with the openwork casing, facilitated the flow of cooling air. This type of design is known as compact (Fig 3).
The alternator design continued to evolve; this also applies to stator winding methods and rectifying radiator design. While the heating of the alternator is hardly a surprise, the magnitude of the heat released is!
The efficiency of commonly used alternators varies between 60% and 75%, and this means that no less than 25% to 40% of the mechanical energy extracted must be additionally lost to generate the required electricity. Some recent alternator designs, thanks to numerous additional modifications, achieve efficiency of about 80%.
The manner of mechanical energy consumption by the alternator is shown in Fig 4. For the estimated calculations, a currently used and manufactured alternator with a rated voltage of 12V and rated current of 140A was selected. Its catalogue efficiency, according to the manufacturer’s data, is a minimum of 65%. Based on numerous publications and my own experiments, the following conclusions can be drawn:
- Approximately half of the electrical energy produced by the alternator is lost through the heat generated within
- The most heat is released in the stator windings
- The diodes in the rectifier bridge give off a significant amount of heat
- Unexpectedly high energy losses in occur the iron – that is, in the metal part of the stator
Energy losses during processing are always a consequence of the design solutions adopted. Due to the mass production of alternators, the choice of design is fundamentally influenced, not only by the conversion efficiency, but above all by its ease of manufacture and the cost of production.
Impact on design
All of these findings have a significant impact on alternator design solutions. The greatest energy loss is due to the heating of the stator winding. Economic considerations and size limitations have led designers to assume a relatively high current density in the stator windings.
Thanks to the introduced constructional change, the blades placed on the rotor provide better cooling of the side parts of the stator windings protruding above the rotor blades (Fig 3).
The more intense air movement also cools the diodes in the rectifier. A rectifying diode is not a perfect rectifier. There is a voltage drop across each diode during current conduction. At any time, the load current flows through at least two diodes. For the alternator in question, the heat released in the rectifier corresponds to a 280W heater.
In a stator, heat is generated not only in its windings but also in the metal core itself. An attempt to reduce the iron loss also has consequences in stator design. The metal part of the stator is part of the magnetic field circuit produced by the alternator’s moving rotor.
In individual fragments of the core, the magnetic field systematically changes its direction with a frequency of up to several hundred hertz (at 3000rpm motor speed the frequency is about 600Hz). This alternating magnetic field causes energy loss for over-fluxing and results in eddy currents that depend, in the second power context, on the frequency. The practical use of this phenomenon is commonly used in induction hobs in our homes. To obtain the needed thermal effects, a field variation frequency of 24kHz was used.
In the case of an alternator, the heat generated is undesirable. If the stator core was made of solid material, like in a frying pan, the energy loss and its heating would be far greater. To limit these phenomena, the stator core is made of thin sheets, electrically insulated between one another. The magnetic flux flowing within the thin sheets causes much smaller eddy currents, reducing the unavoidable energy losses to a large extent.
To further reduce eddy currents and electrical conductivity, the sheets are made from a special grade of steel containing an increased content of silicon compounds. This way of limiting the effects of eddy currents is used in all AC magnetic circuits.
Trends and sustainability
The search for better solutions continues… Some alternator manufacturers already have products in their catalogues with efficiencies approaching 80%. Any success in this area is part of a global trend towards better care for the environment. Higher efficiency means lower fuel consumption.
To reduce fuel consumption, overrunning clutch drive wheels have been used in alternators for many years, utilising the kinetic energy of the alternator rotor when the speed of the ICE is reduced.
In recent developments, the alternator can assist the ICE at rapid acceleration, assist braking and use the braking energy to recharge the battery, and can start the warm ICE instead of the starter.